海湾国家要对引航员登轮安全实施集中检查。一家希腊海事机构给出了如下指南
SQEmarine recommends the following best practice guide for Pilot Transfer Arrangements CICs
1. Is the pilot ladder certified by the manufacturer as complying with the requirements of SOLAS Chapter V, Regulation 23 and IMO Resolution A.1045 (27)? 【引航员梯是有国际标准的ISO 799:2004。要符合】
The requirements in SOLAS V/23, deal with the standards for equipment installed and arrangements for pilot transfers on ships on or after 1 July 2012.The standards adopted by the IMO can be found in IMO Resolution A.1045 (27) “Pilot transfer arrangements”. SOLAS V/23.2.3 additionally states that a pilot ladder shall be certified by the manufacturer as complying with V/23 or “with an international standard acceptable to the Organization” and refers to ISO 799:2004 “Ships and marine technology – pilot ladders”. Compliance with this particular provision of SOLAS V/23 can be met when a manufacturer has certified the pilot ladder complies with either of the above standards, which are not identical.
2. Is there a record kept on board with the date the pilot ladder is placed into service and any repairs carried out? 【对引航员梯的使用和修理要记录,在船】
A record shall be kept on the ship as to the date the identified pilot ladder is placed into service and any repairs effected. Deck Officer on board shall focus on the proper record keeping.
3. Is there a regular inspection carried out and recorded to ensure that the pilot ladder is safe to use?【定期检查】
All arrangements used for pilot transfer including pilot ladder shall efficiently fulfil their purpose of enabling pilots to embark and disembark safely. The pilot ladders shall be kept clean, properly maintained and stowed and shall be regularly inspected to ensure that they are safe to use. They shall be used solely for the embarkation and disembarkation of personnel. All the inspections carried out shall be properly recorded and these records shall be available at any time requested by a PSC Inspector.
4. Is there a permanent marking provided at regular intervals throughout the length of the ladder in order to facilitate the rigging of the ladder to the required height?【软梯要有永久的定长标记】
A permanent marking should be provided at regular interval (e.g. 1 m) throughout the length of the ladder in order to facilitate the rigging of the ladder to the required height. Deck Officer shall ensure that this marking is provided throughout the length of the ladder.
5. Are there means provided to Access to the ship’s deck to ensure safe, convenient and unobstructed passage for any person embarking on?【甲板与软梯接口安全】
Means should be provided to ensure safe, convenient and unobstructed passage for any person embarking on, or disembarking from, the ship between the head of the pilot ladder, or of any accommodation ladder, and the ship’s deck; such access should be gained directly by a platform securely guarded by handrails. Where such passage is by means of:
a gateway in the rails or bulwark, adequate handholds should be provided at the point of embarking on or disembarking from the ship on each side which should be not less than 0.7 m or more than 0.8 m apart. Each handhold should be rigidly secured to the ship’s structure at or near its base and also at a higher point, not less than 32 mm in diameter and extend not less than 1.2 m above the top of the bulwarks. Stanchions or handrails should not be attached to the bulwark ladder,
a bulwark ladder should be securely attached to the ship to prevent overturning. Two handhold stanchions should be fitted at the point of embarking on or disembarking from the ship on each side which should be not less than 0.7 m or more than 0.8 m apart. Each stanchion should be rigidly secured to the ship’s structure at or near its base and also at a higher point, should be not less than 32 mm in diameter and should extend not less than 1.2 m above the top of the bulwarks. Stanchions or handrails should not be attached to the bulwark ladder.
6. Is there a mechanical pilot hoists used?【禁止使用升降机】
The use of mechanical pilot hoists is prohibited by SOLAS regulation V/23 and mechanical pilot hoists shall not be used.
7. Is there a lifebuoy equipped with a self-igniting light in pilot landing platform?【登离轮时自亮灯式救生圈在手边】
When persons are being transferred, a lifebuoy equipped with a self-igniting light shall be kept at hand ready for immediate use. Deck Officer shall confirm that such equipment is provided as requested by regulations.
8. Are there suitable bulwark ladders and stanchions provided?【舷墙梯是否固定】
A bulwark ladder, two handhold stanchions rigidly secured to the ship’s structure at or near their bases and at higher points shall be fitted. The bulwark ladder shall be securely attached to the ship to prevent overturning.
9. Are the steps of the ladders made of hardwood, in one piece and non-slippery?【硬木踏板,应整块制成,无结、防滑处理】
The steps of the pilot ladders should comply with the following requirements:
if made of hardwood, they should be made in one piece, free of knots,
if made of material other than hardwood, they should be of equivalent strength, stiffness and durability to the satisfaction of the Administration and
they should have an efficient non-slip su***ce.
10. Are pilot ladder steps parallel and the last four steps made of rubber of sufficient strength?【最低四级踏板要求很具体】
The steps of the pilot ladders should comply with the following requirements:
the four lowest steps may be of rubber of sufficient strength and stiffness or other material to the satisfaction of the Administration,
they should be not less than 400 mm between the side ropes, 115 mm wide and 25 mm in depth, excluding any non-slip device or grooving,
they should be equally spaced not less than 310 mm or more than 350 mm apart and
they should be secured in such a manner that each will remain horizontal.
11. Are the shipside doors used for pilot transfer opening inwards?【船侧梯门向内开】
In accordance with SOLAS Regulation V/23, paragraph 5, shipside doors used for pilot transfer shall not open outwards but must open inwards.